technical:generic:caviness-gen1-ossnfs-rebuild [2019-07-31 12:27] – [Caviness: Rebuild of First-Generation OSS and NFS Nodes] freytechnical:generic:caviness-gen1-ossnfs-rebuild [2019-07-31 12:28] (current) – [Design of Second-Generation] frey
Line 91: Line 91:
 |internal|1|960 GB SSD|swap, ''/tmp'', ''/var''| |internal|1|960 GB SSD|swap, ''/tmp'', ''/var''|
 |external JBOD|1|480 GB SSD|L2ARC| |external JBOD|1|480 GB SSD|L2ARC|
-|external JBOD|11|12000 GB HDD|RAIDZ2 + hot spare|+|external JBOD|11|12000 GB HDD|RAIDZ2 + hot spare (OSS); RAIDZ3 + hot spare (NFS)|
  
 The L2ARC has been moved to the JBOD, so that each OSS server's partner can also see the device.  The ZIL has been removed altogether, which leaves room for one additional HDD over the first-generation design; the extra HDD together with the larger per-disk HDD capacity makes each second-generation pool 66% larger than the previous generation. The L2ARC has been moved to the JBOD, so that each OSS server's partner can also see the device.  The ZIL has been removed altogether, which leaves room for one additional HDD over the first-generation design; the extra HDD together with the larger per-disk HDD capacity makes each second-generation pool 66% larger than the previous generation.
Line 101: Line 101:
 ===== First-Generation Rebuild ===== ===== First-Generation Rebuild =====
  
-To match the second-generation design, the first-generation nodes' SSDs could be repurposed:+To match the second-generation design, the first-generation nodes' SSDs could be repurposed for the OSSs and OSTs:
  
 ^Physical location^Qty^Device^Purpose^ ^Physical location^Qty^Device^Purpose^