abstract:farber:transfer

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
abstract:farber:transfer [2018-05-23 11:48] – [Copying files to the cluster] anitaabstract:farber:transfer [2021-12-01 11:10] (current) anita
Line 1: Line 1:
-====== Transfer Files to/from Farber ======+====== Transferring files to/from Farber ======
  
 //The following sections use the wiki's [[:#documentation-conventions|documentation conventions]].// //The following sections use the wiki's [[:#documentation-conventions|documentation conventions]].//
Line 36: Line 36:
 </note> </note>
  
-<note warning>For **Windows** clients editing files on Windows desktops and then transferring them back to the cluster, you may find that your file becomes "corrupt" during file transfer process.  The symptoms are very subtle because the file appears to be okay, but in fact contains ''CRLF'' line terminators.  This causes problems when reading the file on a Unix cluster and generates very strange errors. Some examples might be a file used for submitting a batch job such as ''submit.qs'' and one you have used before and know is correct, will no longer work. Or an input file used for ABAQUS like ''tissue.inp'' which has worked many times before produces an error like ''Abaqus Error: Command line option "input" must have a value.''+<note warning>For **Windows** clients editing files on Windows desktops and then transferring them back to the cluster, you may find that your file becomes "corrupt" during file transfer process.  The symptoms are very subtle because the file appears to be okay, but in fact contains ''CRLF'' line terminators.  This causes problems when reading the file on a Linux cluster and generates very strange errors. Some examples might be a file used for submitting a batch job such as ''submit.qs'' and one you have used before and know is correct, will no longer work. Or an input file used for ABAQUS like ''tissue.inp'' which has worked many times before produces an error like ''Abaqus Error: Command line option "input" must have a value.''
  
 Use the utility ''file'' to check for ''CRLF'' line terminators and ''dos2unix'' to fix it, like this below Use the utility ''file'' to check for ''CRLF'' line terminators and ''dos2unix'' to fix it, like this below
Line 85: Line 85:
  
 will copy the directory ''fuelcell'' on the Farber cluster into a new ''fuelcell'' directory in your local system's current working directory. (Note the final period in the command.) will copy the directory ''fuelcell'' on the Farber cluster into a new ''fuelcell'' directory in your local system's current working directory. (Note the final period in the command.)
- 
-//This section uses the wiki's [[:#documentation-conventions|documentation conventions]].// 
 ===== Copying files between clusters ===== ===== Copying files between clusters =====
  
Line 113: Line 111:
 will copy the directory ''fuelcell'' from Mills to a new ''fuelcell'' directory on Farber. will copy the directory ''fuelcell'' from Mills to a new ''fuelcell'' directory on Farber.
  
-//This section uses the wiki's [[:#documentation-conventions|documentation conventions]].// 
  • abstract/farber/transfer.1527090506.txt.gz
  • Last modified: 2018-05-23 11:48
  • by anita